GEO5 Logiciel

Aide contextuelle

Tree
Settings
Program:
Langue:

EN 1998-5

The cyclic resistance is determined from the graphical correlations provided in annex B of EN 1998-5. The graphs show the relationship between the normalized blow count N₁(60) and the cyclic resistance of the soil for different values of fines content.

The program determines the CRR₇.₅ value by interpolating between the relevant curves according to the specified fines content.

The determination of the normalized blow count N₁(60) is based on the procedure described on the SPT page. The method according to EN 1998-5 uses a specific procedure for determining the correction factor CN.

The normalized blow count is determined from the following equation:

where:

where:

σ´v0

-

effective vertical stress at the depth at which the SPT test was performed [kPa]

The standard specifies that the normalization coefficient CN shall be no less than 0.5 and no greater than 2.0:

Note: The GEO5 program does not limit the calculated value of CN however, if it falls outside the specified range, it is highlighted in red in the detailed results. The calculation then continues using the calculated value. Results obtained outside the range recommended by the standard should therefore be interpreted with caution.

The resulting CRR₇.₅ value corresponds to a reference earthquake with a magnitude of Ms = 7.5. For earthquakes with a different magnitude, the values obtained from the graph are adjusted using the CM correction factor.

For depths shallower than 3 m, EN 1998-5 recommends reducing the measured SPT blow count N by 25%. In the program, this correction is available as an optional setting in the "Liquefaction" panel.

Sources:

EN1998-5

Essayez GEO5 gratuitement.